OPTIMED
sinus-XL Stent
- Stenoses and dissections of the aorta
- Vena Cava-Sydrome
- Obstructions of the Vena Cava
- Endoleak Typ 1a and 1b
Self-expanding Nitinol Stent System
- 10F Application device
- Adapeted to .035 inch guide wire
- Unique range of sizes from Ø 16 mm to 36 mm and lengths from 30 mm to 100 mm
inus-SuperFlex-635
The unique super-flexible 6F stent in sinus-Micro-Mesh design.
- Superflexible nitinol stent with high quality electro-polishing
- 6F application system adapted to a .035i guide wire
- Diameters from 6 to 12 mm and lengths from 30 to 180 mm
sinus-XL Flex
sinus-XL 6F
sinus-SuperFlex-418
Adapted to .018 inch guide wire
Open cell design
Range of sizes from Ø 3 mm – 8 mm and lengths from 30 mm – 200 mm
inus-SuperFlex-518
5 F Application device, 180 cm usable length
Adapted to .018 inch guide wire
Open cell design
Range of sizes from Ø 6 mm – 10 mm and lengths of 40 mm, 60 mm and 80 mm
sinus-SuperFlex-535
5 F Application device
Adapted to .035 inch guide wire
Open cell design
Range of sizes from Ø 4 mm – 10 mm and lengths from 30 mm to 80 mm
sinus-Repo-Visual 6F
Adapted to .035 inch guide wire
Closed cell design
Repositionable
Range of sizes from Ø 6 mm – 14 mm and lengths from 30 mm and 100 mm
sinus-ReductionStent
Reducing the bloodflow following preparation of the TIPS-Stent
- With the indication related hourglass-design and deliberate oversizing of the sinus-ReductionStent, an immediate and controlled reduction of blood flow can be achieved
- Optimized expansion and asymmetric shape of the sinus- ReductionStent facilitate the positioning and repositioning
- 10F application device, adapted to .035 inch guide wire
sinus-DS
sinus-XL Stent
- Stenoses and dissections of the aorta
- Vena Cava-Sydrome
- Obstructions of the Vena Cava
- Endoleak Typ 1a and 1b
Self-expanding Nitinol Stent System
- 10F Application device
- Adapeted to .035 inch guide wire
- Unique range of sizes from Ø 16 mm to 36 mm and lengths from 30 mm to 100
us-Venous
NyloTrack-18
NyloTrack-35
Zelos PTA – Balloon Catheter
Usable shaft length 100 cm
Balloon Ø 12 mm – 28 mm
Balloonlength 20 mm and 40 mm
Mars PTA – Balloon Catheter
Introducer size 5F; 6F
Usable shaft length 75 cm; 120 cm
Balloon Ø 3 mm – 10 mm
Balloon length 20 mm – 100 mm
Dilexx-18
Non-compliant PTA-Ballonnkatheter with radiopaque soft tip and flexible, kink-resistant shaft for transradial and transbrachial approach
- 5F recommended introducer sheath
- Shaft length 180 cm
- Balloon diameters from 5 mm up to 8mm
- Balloon lengths 40 mm and 60 mm
Zelos PTA – Balloon Catheter
Introducer size 6F – 12F
Usable shaft length 100 cm
Balloon Ø 12 mm – 28 mm
Balloonlength 20 mm and 40 mm
AltaFlow Measuring Catheter
- for intravascular measurements
- can be used as a flush-catheter at the same time
- up to a burst pressure of 1,050 PSI
- high radiopacity
- tungsten markers and tip for use in MR procedures
AltaFlow Premium DSA-Catheter
- Excellent radiopaque tip
- High flow rates
- High lubrication properties
Epsylar – Percutaneous Introducer Sheath
Optimal flexibility and maximal pushability for a safe navigation through tortuous vessels and across the bifurcation
Percutaneous Introducer Sheath
- Sheath with removable haemostatic valve
- 3-way stop cock
- Dilator
Percutaneous Introducer Sheath
- Sheath with removable haemostatic valve
- 3-way stop cock
- Dilator
Percutaneous Introducer Sheath Set
- Sheath with haemostatic valve
- 3-way stop cock
- Dilator
- Guide wire double ended, J-curved, 40 cm
- Angiography needle
BigLumen Aspiration Catheter
BigLumen Aspiration Catheter Set
ogLysis – Lysis Catheter
TIPS Puncture Set „Standard“ (30°)
- Ideal torque stability
- 30° curved needle configuration
- Ultrasound visibility due to sandblasting
- Maximized sharpness of needle due to pencil-cut
- Perfect adaption of guiding catheter, puncture needle and accessory
- Optimal configuration and stability of guiding catheter
TIPS Puncture Set „Standard“ (60°)
- Ideal torque stability
- 60° curved needle configuration
- Ultrasound visibility due to sandblasting
- Maximized sharpness of needle due to pencil-cut
- Perfect adaption of guiding catheter, puncture needle and accessory
- Optimal configuration and stability of guiding catheter
TIPS Puncture Set „Special 1“
- Ideal torque stability
- 30° or 60° curved needle configuration
- Ultrasound visibility due to sandblasting
- Maximized sharpness of needle due to Colapinto-cut
- Perfect adaption of guiding catheter, puncture needle and accessory
- Optimal configuration and stability of guiding catheter
TIPS Puncture Set „Special 1“
- Ideal torque stability
- 30° or 60° curved needle configuration
- Ultrasound visibility due to sandblasting
- Maximized sharpness of needle due to Colapinto-cut
- Perfect adaption of guiding catheter, puncture needle and accessory
- Optimal configuration and stability of guiding catheter
Plywire Soft Tip
Nitinol guide wire with highly flexible tip and excellent lubricity for a safe and quick navigation
- Lengths up to 400 cm, also for transradial or transbarchial approach
- Rounded atraumatic soft tip
- Coiled tip with platinum wire and tapered Nitinol core
PTFE Coated Guide Wires
Available in 5 different versions:
- Guide wire straight, fixed core, flexible tip
- Guide wire J-curved, fixed core
- Guide wire straight, fixed core, flexible tip
- Guide wire straight with moveable core
- Guide wire J-curved with moveable core
Dilators
Made of PP (Polypropylene) material and provided with a standard Luer-Lock which enables the injection of contrast media and other solutions.
rydo Haemostatic Valve
Angiography Needles
- Stylet
- US-Cut
initial Puncture Needles
Chiba Needle
available with bevel-edged Cut or US-Cut.
CO2-Take-off Pressure Reduction Valve
Now the CO2 Angioset can also be used with your central gas supply. The specially designed CO2-Take-off Pressure Reduction Valve is equipped with a clamping rail bracket for easy mounting on equipment rails (e.g. OR table) and offers with the 6m hose a wide operating range
CO2-Angioset acc. to Schmitz-Rode/Alzen
CO2 for angiography is a safe alternative to iodine-based or low-osmolar contrast media. It is ideally suited for use in diagnostic and interventional radiology for patients with renal insufficiency, hyperthyroidism, or with an intolerance to contrast-media. Its use is as straight forward as with a conventional DSA.
CO2-Pressure Reduction Valve