Vascular

OPTIMED

sinus-XL Stent

  • Stenoses and dissections of the aorta
  • Vena Cava-Sydrome
  • Obstructions of the Vena Cava
  • Endoleak Typ 1a and 1b

Self-expanding Nitinol Stent System

  • 10F Application device
  • Adapeted to .035 inch guide wire
  • Unique range of sizes from Ø 16 mm to 36 mm and lengths from 30 mm to 100 mm

inus-SuperFlex-635

The unique super-flexible 6F stent in sinus-Micro-Mesh design.

  • Superflexible nitinol stent with high quality electro-polishing
  • 6F application system adapted to a .035i guide wire
  • Diameters from 6 to 12 mm and lengths from 30 to 180 mm

sinus-XL Flex

The perfect solution for curved vessel segments of the aorta and vena cava

sinus-XL 6F

The perfect solution for straight vessel segments of the aorta and vena cava: Aortic stenoses and dissections, Vena cava compression syndrome, Endoleak type 1a and 1b

sinus-SuperFlex-418

4F Application device
Adapted to .018 inch guide wire
Open cell design
Range of sizes from Ø 3 mm – 8 mm and lengths from 30 mm – 200 mm

inus-SuperFlex-518

Transradial & Transbrachial The unique Nitinol Stent System – specifically developed for the transradial or transbrachial approach
5 F Application device, 180 cm usable length
Adapted to .018 inch guide wire
Open cell design
Range of sizes from Ø 6 mm – 10 mm and lengths of 40 mm, 60 mm and 80 mm

sinus-SuperFlex-535

Worldwide First 5F Self-expanding Nitinol Stent System Adapted to .035 inch Guide Wire
5 F Application device
Adapted to .035 inch guide wire
Open cell design
Range of sizes from Ø 4 mm – 10 mm and lengths from 30 mm to 80 mm

sinus-Repo-Visual 6F

6F Application device
Adapted to .035 inch guide wire
Closed cell design
Repositionable
Range of sizes from Ø 6 mm – 14 mm and lengths from 30 mm and 100 mm

sinus-ReductionStent

Reducing the bloodflow following preparation of the TIPS-Stent

  • With the indication related hourglass-design and deliberate oversizing of the sinus-ReductionStent, an immediate and controlled reduction of blood flow can be achieved
  • Optimized expansion and asymmetric shape of the sinus- ReductionStent facilitate the positioning and repositioning
  • 10F application device, adapted to .035 inch guide wire

sinus-DS

Self-expanding nitinol stent for treatment of Hypoplastic Left Heart Syndrome (HLHS)

sinus-XL Stent

  • Stenoses and dissections of the aorta
  • Vena Cava-Sydrome
  • Obstructions of the Vena Cava
  • Endoleak Typ 1a and 1b

Self-expanding Nitinol Stent System

  • 10F Application device
  • Adapeted to .035 inch guide wire
  • Unique range of sizes from Ø 16 mm to 36 mm and lengths from 30 mm to 100

us-Venous

MAXIMUM POWER & FLEXIBILITY

NyloTrack-18

Semi-compliant nylon PTA – balloon catheter available in 2 to 7 mm in diameter and from 20 to 220 mm in length

NyloTrack-35

Semi-compliant nylon balloon available in 3 to 10 mm in diameter and from 20 to 150 mm in length

Zelos PTA – Balloon Catheter

The Big One – up to à˜ 28 mm Introducer size 6F – 12F
Usable shaft length 100 cm
Balloon Ø 12 mm – 28 mm
Balloonlength 20 mm and 40 mm

Mars PTA – Balloon Catheter

High Pressure Performance non-compliant balloon
Introducer size 5F; 6F
Usable shaft length 75 cm; 120 cm
Balloon Ø 3 mm – 10 mm
Balloon length 20 mm – 100 mm

Dilexx-18

the low profile expert
Non-compliant PTA-Ballonnkatheter with radiopaque soft tip and flexible, kink-resistant shaft for transradial and transbrachial approach

  • 5F recommended introducer sheath
  • Shaft length 180 cm
  • Balloon diameters from 5 mm up to 8mm
  • Balloon lengths 40 mm and 60 mm

Zelos PTA – Balloon Catheter

The Big One – up to à˜ 28 mm
Introducer size 6F – 12F
Usable shaft length 100 cm
Balloon Ø 12 mm – 28 mm
Balloonlength 20 mm and 40 mm

AltaFlow Measuring Catheter

  • for intravascular measurements
  • can be used as a flush-catheter at the same time
  • up to a burst pressure of 1,050 PSI
  • high radiopacity
  • tungsten markers and tip for use in MR procedures

AltaFlow Premium DSA-Catheter

  • Excellent radiopaque tip
  • High flow rates
  • High lubrication properties

Epsylar – Percutaneous Introducer Sheath

New size: now also available in 4F
Optimal flexibility and maximal pushability for a safe navigation through tortuous vessels and across the bifurcation

Percutaneous Introducer Sheath

  • Sheath with removable haemostatic valve
  • 3-way stop cock
  • Dilator

Percutaneous Introducer Sheath

  • Sheath with removable haemostatic valve
  • 3-way stop cock
  • Dilator

Percutaneous Introducer Sheath Set

  • Sheath with haemostatic valve
  • 3-way stop cock
  • Dilator
  • Guide wire double ended, J-curved, 40 cm
  • Angiography needle

BigLumen Aspiration Catheter

for the percutaneous Aspiration-Thromboembolectomy to ease the removal of thromboembolic material

BigLumen Aspiration Catheter Set

for the percutaneous Aspiration-Thromboembolectomy to ease the removal of thromboembolic material

ogLysis – Lysis Catheter

Lysis catheter with logarythmic design for equal lysis from each side hole

TIPS Puncture Set „Standard“ (30°)

  • Ideal torque stability
  • 30° curved needle configuration
  • Ultrasound visibility due to sandblasting
  • Maximized sharpness of needle due to pencil-cut
  • Perfect adaption of guiding catheter, puncture needle and accessory
  • Optimal configuration and stability of guiding catheter

TIPS Puncture Set „Standard“ (60°)

  • Ideal torque stability
  • 60° curved needle configuration
  • Ultrasound visibility due to sandblasting
  • Maximized sharpness of needle due to pencil-cut
  • Perfect adaption of guiding catheter, puncture needle and accessory
  • Optimal configuration and stability of guiding catheter

TIPS Puncture Set „Special 1“

  • Ideal torque stability
  • 30° or 60° curved needle configuration
  • Ultrasound visibility due to sandblasting
  • Maximized sharpness of needle due to Colapinto-cut
  • Perfect adaption of guiding catheter, puncture needle and accessory
  • Optimal configuration and stability of guiding catheter

TIPS Puncture Set „Special 1“

  • Ideal torque stability
  • 30° or 60° curved needle configuration
  • Ultrasound visibility due to sandblasting
  • Maximized sharpness of needle due to Colapinto-cut
  • Perfect adaption of guiding catheter, puncture needle and accessory
  • Optimal configuration and stability of guiding catheter

Plywire Soft Tip

Nitinol guide wire with highly flexible tip and excellent lubricity for a safe and quick navigation

  • Lengths up to 400 cm, also for transradial or transbarchial approach
  • Rounded atraumatic soft tip
  • Coiled tip with platinum wire and tapered Nitinol core

PTFE Coated Guide Wires

Available in 5 different versions:

  • Guide wire straight, fixed core, flexible tip
  • Guide wire J-curved, fixed core
  • Guide wire straight, fixed core, flexible tip
  • Guide wire straight with moveable core
  • Guide wire J-curved with moveable core

Dilators

Dilators for Vessel Dilation
Made of PP (Polypropylene) material and provided with a standard Luer-Lock which enables the injection of contrast media and other solutions.

rydo Haemostatic Valve

Hämostatic valve with Standard Luer-Lock, 18 cm tube and detachable 3-way stop coc

Angiography Needles

  • Stylet
  • US-Cut

initial Puncture Needles

The combination of a specially cut cannula and modified stylet guarantees excellent visibility of the tip under ultrasound.

Chiba Needle

The combination of a specially cut cannula and modified stylet guarantees excellent visibility of the tip under ultrasound.
available with bevel-edged Cut or US-Cut.

CO2-Take-off Pressure Reduction Valve

The pressure reduction valve dedicated for wall connection
Now the CO2 Angioset can also be used with your central gas supply. The specially designed CO2-Take-off Pressure Reduction Valve is equipped with a clamping rail bracket for easy mounting on equipment rails (e.g. OR table) and offers with the 6m hose a wide operating range

CO2-Angioset acc. to Schmitz-Rode/Alzen

Economical – Easy Handling – Excellent Image
CO2 for angiography is a safe alternative to iodine-based or low-osmolar contrast media. It is ideally suited for use in diagnostic and interventional radiology for patients with renal insufficiency, hyperthyroidism, or with an intolerance to contrast-media. Its use is as straight forward as with a conventional DSA.

CO2-Pressure Reduction Valve

The CO2 Pressure Reduction Valve is pre-set to 1.3 bar and enables a safe withdrawal of pure medical carbon dioxide from gas bottles or online wall connections. The two-stage pressure reduction valve maintains a safe and constant pressure and features a safety and release valve.